The use of fast rolling shutter door frequency converterIssuing time:2023-10-10 15:44 C150: Set the descent delay time from 0 to 9999, and the factory value is 5 (5S) Explanation: When the working mode is in travel mode, if it is in automatic mode, C15O determines the delay time for the rapid rolling shutter door body to descend. If C150=9999, the door will stop at the upper limit position and no longer lower, otherwise the high-speed door frequency converter will lower after the delay time of C150. C151: (Travel mode) Up low speed running time 0-10.0S, factory value is 1.0 (1S) C152: (Travel mode) Lowering low-speed operation time 0-10.0S, factory value is 1.0 (1S) C153: Input port status monitoring 1, factory value* Description: This parameter is used to monitor the status of the external input port, with "1" indicating on and "0" indicating off The specific display instructions for the four LEDs are as follows: LED4 → VI (manual/automatic), LED3 → SPH (radar), LED2 → SPM (up limit), LED1 → SPL (down limit) C154: Input port status monitoring 2, factory value* Description: This parameter is used to monitor the status of the external input port, with "1" indicating on and "0" indicating off The specific display instructions for the four LEDs are as follows: LED4 → VI (manual/automatic), LED3 → SPH (radar), LED2 → FOR (up button), LED1 → REV (down button) C155: Select control mode: 0,1,2, factory value is 1 0: Universal standard mode, 1: Travel switch mode, 2: Value encoder mode Note: When C155=1, if C168 is also 1, the keyboard will display an A.PR error C156: Encoder installation position: 0,1, factory value is 0 0: Left, 1: Right C157: Quick rolling shutter door frequency converter expansion parameter mode: 0-1, factory value is 1 Note: If the value of C157 is 1, the parameters before C150 cannot be monitored or modified C158: Definition of VI input state: 0-1, factory value is 0 Explanation: In travel mode, the VI port is only used to represent manual/automatic mode, and is independent of the setting value of the C158 parameter In encoder mode, C158 is used for manual/automatic, full/half open: 0: Manual/automatic selection: Select the half open mode, and after connecting, press the time delay set by C150 to decrease. When disconnecting, cancel the delay 1: Half open/full open: Select the half open/full open mode, fully open when connected, and half open when disconnected At this point, when the time set by C150 is not equal to 9999, the delay decreases; Otherwise, cancel the delay descent C159: Restore factory value 08 Factory value*
|